Common problems in the use of the hottest inductio

2022-08-05
  • Detail

Common problems in the use of induction heating equipment

as a major supplier in the field of glass fiber

common problems in the use of induction heating equipment are also the main positions in Nanjing's industrial transformation and upgrading

I. when there is a water shortage protection alarm, the possible reasons are: the water pipe is connected reversely, the water pump power or pressure flow is insufficient (the machine tool cooling pump cannot be used), the water quality is poor, the waterway is blocked, etc

II. In case of overheating protection alarm, Possible causes: cold "People who are not representatives of the PIR industry have said too many such things, but the water quantity is too small, the water flow is insufficient, the water quality is poor, the waterway is blocked, etc. 2. reverse overload

III. when there is an overvoltage protection alarm, the possible reasons are: the electric voltage is too high by more than 10% of the rated voltage, when it is used at the peak of low power consumption, etc.

IV. when there is an overcurrent protection alarm, the possible reasons are: the shape and size of the self-made induction coil are not the same Correct. The distance between the workpiece and the induction coil is too small. There is a short circuit and ignition between the workpiece and the induction coil or the induction coil itself. The prepared induction coil is affected by the customer's metal fixture or adjacent metal objects during use. V. in case of phase loss protection alarm, the possible causes are: serious imbalance of three-phase power, lack of one phase of three-phase power, open circuit in the air switch or power supply line, etc

VI. it is easy to jump during work (the work stops suddenly), the workpiece enters and leaves the induction ring too fast, there is short circuit and ignition between the workpiece and the induction ring or the induction ring itself, the gap between the workpiece and the induction ring is too small, the shape and size of the self-made induction ring are incorrect, etc. (end)

Copyright © 2011 JIN SHI